What is a Hot Water Heater TPR Valve and Why Should It Be Inspected?

TPR Valve on side of Hot Water Tank
TPR Valve on side of Hot Water Tank

A Temperature and Pressure Relief (TPR) valve (also known as T&P) is a crucial safety component of a water heater. It is designed to release water if the temperature or pressure inside the tank exceeds safe levels, preventing potential explosions or damage to the water heater.

 


How Does a TPR Valve Work?

The TPR valve is typically located on the top or side of the water heater. It is connected to a discharge pipe that directs excess water safely away. When the water temperature rises above 210°F or the pressure exceeds 150 psi, the valve automatically opens to release the excess pressure, ensuring the system remains stable and safe.



Why is a TPR Valve Inspection Important?

Regular inspection of the TPR valve is essential for several reasons:

  1. Prevents Dangerous Pressure Build-Up

    If the valve fails to open, excessive pressure inside the tank can lead to an explosion, causing severe property damage or injury.

  2. Ensures Proper Functionality

    Over time, mineral buildup, corrosion, or mechanical failure can cause the valve to stick, rendering it ineffective when needed.

  3. Avoids Costly Water Damage

    A leaking or faulty TPR valve can cause continuous water discharge, leading to potential flooding, increased water bills, and structural damage.


How to Inspect a TPR Valve

Homeowners can perform a basic check, but a professional inspection is recommended at least once a year. Here’s how to check the valve:

  1. Turn Off Power and Water Supply

    If testing manually, ensure safety by turning off the water supply and shutting off the heater's power source

  2. Lift the Valve’s Lever

    Gently lift the lever on the valve; you should hear or see water flow through the discharge pipe.  Consider having a small pail at the end of the discharge pipe to capture the water.  Since the water will be coming straight out of the Hot Water tank, it will be very hot.

  3. Check for Proper Operation

    Once released, the valve should snap back into place and stop discharging water.  If it drips continuously, it may be faulty and require replacement.

  4. Look for Corrosion or Blockages

    Inspect the valve and discharge pipe for any rust, debris, or obstructions that may hinder proper function.


When to Replace a TPR Valve

  • If the valve is leaking continuously even after testing.

  • If it does not release water when manually tested.

  • If there is visible corrosion or mineral buildup around the valve.

  • If the valve is more than 3–5 years old without prior testing or maintenance.


Final Thoughts

The TPR valve is a small but vital component in ensuring the safety and longevity of your water heater. Regular inspections help prevent potential hazards and costly repairs. If you suspect an issue, it’s best to consult a licensed plumber or home inspector to evaluate and replace the valve if necessary.

Have you checked your water heater’s TPR valve recently? A quick inspection today could prevent a disaster tomorrow!



 
 
 